Int J Environ Res Public Health ; 20(8)2023 04 11.
Article in English | MEDLINE | ID: covidwho-2293149

ABSTRACT

Airborne viruses, such as COVID-19, cause pandemics all over the world. Virus-containing particles produced by infected individuals are suspended in the air for extended periods, actually resulting in viral aerosols and the spread of infectious diseases. Aerosol collection and detection devices are essential for limiting the spread of airborne virus diseases. This review provides an overview of the primary mechanisms and enhancement techniques for collecting and detecting airborne viruses. Indoor virus detection strategies for scenarios with varying ventilations are also summarized based on the excellent performance of existing advanced comprehensive devices. This review provides guidance for the development of future aerosol detection devices and aids in the control of airborne transmission diseases, such as COVID-19, influenza and other airborne transmission viruses.


Subject(s)
COVID-19 , Influenza, Human , Viruses , Humans , COVID-19/diagnosis , Respiratory Aerosols and Droplets , Pandemics/prevention & control
2.
Front Public Health ; 10: 1022055, 2022.
Article in English | MEDLINE | ID: covidwho-2237021

ABSTRACT

The coronavirus disease (COVID-19) outbreak has turned the world upside down bringing about a massive impact on society due to enforced measures such as the curtailment of personal travel and limitations on economic activities. The global pandemic resulted in numerous people spending their time at home, working, and learning from home hence exposing them to air contaminants of outdoor and indoor origins. COVID-19 is caused by the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), which spreads by airborne transmission. The viruses found indoors are linked to the building's ventilation system quality. The ventilation flow in an indoor environment controls the movement and advection of any aerosols, pollutants, and Carbon Dioxide (CO2) created by indoor sources/occupants; the quantity of CO2 can be measured by sensors. Indoor CO2 monitoring is a technique used to track a person's COVID-19 risk, but high or low CO2 levels do not necessarily mean that the COVID-19 virus is present in the air. CO2 monitors, in short, can help inform an individual whether they are breathing in clean air. In terms of COVID-19 risk mitigation strategies, intelligent indoor monitoring systems use various sensors that are available in the marketplace. This work presents a review of scientific articles that influence intelligent monitoring development and indoor environmental quality management system. The paper underlines that the non-dispersive infrared (NDIR) sensor and ESP8266 microcontroller support the development of low-cost indoor air monitoring at learning facilities.


Subject(s)
Air Pollution, Indoor , COVID-19 , Humans , SARS-CoV-2 , COVID-19/epidemiology , COVID-19/prevention & control , Carbon Dioxide , Air Pollution, Indoor/prevention & control , Air Pollution, Indoor/analysis , Respiratory Aerosols and Droplets
3.
Interface Focus ; 12(2): 20210063, 2022 Apr 06.
Article in English | MEDLINE | ID: covidwho-1713822

ABSTRACT

Poor housing conditions are known to be associated with infectious diseases such as high Coronavirus disease 2019 (COVID-19) incidences. Transmission causes of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in poor housing conditions can be complex. An understanding of the exact mechanism of transmission can help to pinpoint contributing environmental issues. Here, we investigated a Hong Kong COVID-19 outbreak in early 2021 in four traditional Tong Lau houses with subdivided units. There are more than 80 subdivided units of less than 20 m2 floor area each on average. With a total of 34 confirmed COVID-19 cases, the outbreak had an attack rate of 25.4%, being one of the highest attack rates observed in Hong Kong, and ranked among the highest attack rates in reported outbreaks internationally. Tracer gas leakage and decay measurements were performed in the drainage system and in the subdivided units to determine the transport of infectious aerosols by the owner-modified sophisticated wastewater drainage pipe networks and the poor ventilation conditions in some subdivided units. The results show that the outbreak was probably due to multiple transmission routes, i.e. by the drainage pipe spread of stack aerosols, which is enhanced by poor ventilation in the subdivided units.

4.
Build Environ ; 207: 108495, 2022 Jan.
Article in English | MEDLINE | ID: covidwho-1641148

ABSTRACT

Recent evidence suggests that SARS-CoV-2, which is the virus causing a global pandemic in 2020, is predominantly transmitted via airborne aerosols in indoor environments. This calls for novel strategies when assessing and controlling a building's indoor air quality (IAQ). IAQ can generally be controlled by ventilation and/or policies to regulate human-building-interaction. However, in a building, occupants use rooms in different ways, and it may not be obvious which measure or combination of measures leads to a cost- and energy-effective solution ensuring good IAQ across the entire building. Therefore, in this article, we introduce a novel agent-based simulator, ArchABM, designed to assist in creating new or adapt existing buildings by estimating adequate room sizes, ventilation parameters and testing the effect of policies while taking into account IAQ as a result of complex human-building interaction patterns. A recently published aerosol model was adapted to calculate time-dependent carbon dioxide (CO2) and virus quanta concentrations in each room and inhaled CO2 and virus quanta for each occupant over a day as a measure of physiological response. ArchABM is flexible regarding the aerosol model and the building layout due to its modular architecture, which allows implementing further models, any number and size of rooms, agents, and actions reflecting human-building interaction patterns. We present a use case based on a real floor plan and working schedules adopted in our research center. This study demonstrates how advanced simulation tools can contribute to improving IAQ across a building, thereby ensuring a healthy indoor environment.

5.
Build Environ ; 211: 108751, 2022 Mar 01.
Article in English | MEDLINE | ID: covidwho-1588178

ABSTRACT

In order to control the spread of Covid-19, authorities provide various prevention guidelines and recommendations for health workers and the public. Personal protection equipment (PPE) and physical barrier are the most widely applied prevention measures in practice due to their affordability and ease of implementation. This study aims to investigate the effect of PPE and physical barriers on mitigating the short-range airborne transmission between two people in a ventilated environment. Four types of PPE (surgical mask, two types of face shield, and mouth visor), and two different sizes of the physical barrier were tested in a controlled environment with two life-size breathing thermal manikins. The PPE was worn by the source manikin to test the efficiency of source control. The measurement results revealed that the principles of PPE on preventing short-range droplet and airborne transmission are different. Instead of filtering the fine droplet nuclei, they mainly redirect the virus-laden exhalation jet and avoid the exhaled flow entering the target's inhalation region. Physical barriers can block the spreading of droplet nuclei and create a good micro environment at short distances between persons. However, special attention should be paid to arranging the physical barrier and operating the ventilation system to avoid the stagnant zone where the contaminant accumulates.

6.
Build Environ ; 198: 107839, 2021 Jul.
Article in English | MEDLINE | ID: covidwho-1184861

ABSTRACT

An outbreak of COVID-19 occurred on the Diamond Princess cruise ship in January and February 2020 in Japan. We analysed information on the cases of infection to infer whether airborne transmission of SARS-CoV-2, the causative agent of COVID-19, had occurred between cabins. We infer from our analysis that most infections in passengers started on 28 January and were completed by 6 February, except in those who shared a cabin with another infected passenger. The distribution of the infected cabins was random, and no spatial cluster of the infected can be identified. We infer that the ship's central air-conditioning system for passenger's cabins did not play a role in SARS-CoV-2 transmission, i.e. airborne transmission did not occur between cabins during the outbreak, suggesting that the sufficient ventilation was provided. We also infer that the ship's cabin drainage system did not play a role. Most transmission appears to have occurred in the public areas of the cruise ship, likely due to crowding and insufficient ventilation in some of these areas.

7.
Proc Math Phys Eng Sci ; 477(2247): 20200855, 2021 Mar.
Article in English | MEDLINE | ID: covidwho-1165605

ABSTRACT

The year 2020 has seen the emergence of a global pandemic as a result of the disease COVID-19. This report reviews knowledge of the transmission of COVID-19 indoors, examines the evidence for mitigating measures, and considers the implications for wintertime with a focus on ventilation.

8.
Build Environ ; 196: 107788, 2021 Jun.
Article in English | MEDLINE | ID: covidwho-1128907

ABSTRACT

Although airborne transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been recognized, the condition of ventilation for its occurrence is still being debated. We analyzed a coronavirus disease 2019 (COVID-19) outbreak involving three families in a restaurant in Guangzhou, China, assessed the possibility of airborne transmission, and characterized the associated environmental conditions. We collected epidemiological data, obtained a full video recording and seating records from the restaurant, and measured the dispersion of a warm tracer gas as a surrogate for exhaled droplets from the index case. Computer simulations were performed to simulate the spread of fine exhaled droplets. We compared the in-room location of subsequently infected cases and spread of the simulated virus-laden aerosol tracer. The ventilation rate was measured using the tracer gas concentration decay method. This outbreak involved ten infected persons in three families (A, B, C). All ten persons ate lunch at three neighboring tables at the same restaurant on January 24, 2020. None of the restaurant staff or the 68 patrons at the other 15 tables became infected. During this occasion, the measured ventilation rate was 0.9 L/s per person. No close contact or fomite contact was identified, aside from back-to-back sitting in some cases. Analysis of the airflow dynamics indicates that the infection distribution is consistent with a spread pattern representative of long-range transmission of exhaled virus-laden aerosols. Airborne transmission of the SARS-CoV-2 virus is possible in crowded space with a ventilation rate of 1 L/s per person.

9.
Build Environ ; 193: 107659, 2021 Apr 15.
Article in English | MEDLINE | ID: covidwho-1077807

ABSTRACT

SARS-CoV-2 can spread by close contact through large droplet spray and indirect contact via contaminated objects. There is mounting evidence that it can also be transmitted by inhalation of infected saliva aerosol particles. These particles are generated when breathing, talking, laughing, coughing or sneezing. It can be assumed that aerosol particle concentrations should be kept low in order to minimize the potential risk of airborne virus transmission. This paper presents measurements of aerosol particle concentrations in a gym, where saliva aerosol production is pronounced. 35 test persons performed physical exercise and aerosol particle concentrations, CO2 concentrations, air temperature and relative humidity were obtained in the room of 886 m³. A separate test was used to discriminate between human endogenous and exogenous aerosol particles. Aerosol particle removal by mechanical ventilation and mobile air cleaning units was measured. The gym test showed that ventilation with air-change rate ACH = 2.2 h-1, i.e. 4.5 times the minimum of the Dutch Building Code, was insufficient to stop the significant aerosol concentration rise over 30 min. Air cleaning alone with ACH = 1.39 h-1 had a similar effect as ventilation alone. Simplified mathematical models were engaged to provide further insight into ventilation, air cleaning and deposition. It was shown that combining the above-mentioned ventilation and air cleaning can reduce aerosol particle concentrations with 80 to 90% , depending on aerosol size. This combination of existing ventilation supplemented with air cleaning is energy efficient and can also be applied for other indoor environments.

10.
Build Environ ; 180: 107022, 2020 Aug.
Article in English | MEDLINE | ID: covidwho-437350

ABSTRACT

Within a time span of only a few months, the SARS-CoV-2 virus has managed to spread across the world. This virus can spread by close contact, which includes large droplet spray and inhalation of microscopic droplets, and by indirect contact via contaminated objects. While in most countries, supermarkets have remained open, due to the COVID-19 pandemic, authorities have ordered many other shops, restaurants, bars, music theaters and indoor sports centers to be closed. As part of COVID-19 (semi)lock-down exit strategies, many government authorities are now (May-June 2020) allowing a gradual re-opening, where sometimes indoor sport centers are last in line to be permitted to re-open. This technical note discusses the challenges in safely re-opening these facilities and the measures already suggested by others to partly tackle these challenges. It also elaborates three potential additional measures and based on these additional measures, it suggests the concept of a certificate of equivalence that could allow indoor sports centers with such a certificate to re-open safely and more rapidly. It also attempts to stimulate increased preparedness of indoor sports centers that should allow them to remain open safely during potential next waves of SARS-CoV-2 as well as future pandemics. It is concluded that fighting situations such as the COVID-19 pandemic and limiting economic damage requires increased collaboration and research by virologists, epidemiologists, microbiologists, aerosol scientists, building physicists, building services engineers and sports scientists.